We Rebranded! Looking for a W-9, payment info or something else?CLICK HERE FOR RESOURCES

homepage

Ferraz Shawmut - Mersen 132 100-30A FUSE REDUCER PR

CopyCopy
Ferraz Shawmut - Mersen 132 100-30A FUSE REDUCER PR

Login or create an account to check prices & order

Essential specifications

  • 12-Digit UPC - 782001752248

  • Applications - Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications.

  • Catalog Number - 132

  • Class - H and K

  • ERP_productname - FRZ 132 100-30A FUSE REDUCER PR

Packaging

  • 1 ea

EAN

00782001752248

Part #

179569

Catalog #

132

Commercial reference

132

12-Digit UPC:

782001752248

Applications:

Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications.

Catalog Number:

132

Class:

H and K

ERP_productname:

FRZ 132 100-30A FUSE REDUCER PR

Family Brand Name:

Ferraz Shawmut Canada, Inc.

Type:

Non-Rejection

Voltage:

600 Volt

SoneparProductId:

SKU_US_52640643

Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications.