  • 12-Digit UPC - 785901752561

  • Catalog Number - EX300T212H

  • Country of Origin - USA

  • Depths - 832 mm

  • ERP_productname - SQD EX300T212H DOE 2016 LV XFMR, 3 PHASE, 300KVA, 208 DELTA-480Y/277, AL, 150C RISE-220C INS

Packaging

  • 1 ea

EAN

00785901752561

Part #

166196

Catalog #

EX300T212H

Commercial reference

EX300T212H

12-Digit UPC:

785901752561

Catalog Number:

EX300T212H

Country of Origin:

USA

Depths:

832 mm

ERP_productname:

SQD EX300T212H DOE 2016 LV XFMR, 3 PHASE, 300KVA, 208 DELTA-480Y/277, AL, 150C RISE-220C INS

Family Brand Name:

Square D

Heights:

1461 mm

Material:

Aluminum

Number of Phases:

3 Phase

Primary Voltage:

208 V

Secondary Voltage:

277 V

Voltage:

208 Volt

Widths:

1018 mm

SoneparProductId:

SKU_US_29636099

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 300kVA, 208V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer.s DOE 2016 and NRCan efficiency is a minimum of 99.02% at 35% loading and 75.C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of . inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values. Prop 65: WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov - Compatible Products: 7400WS25J; 7400FMB; 7400DS25J