We Rebranded! Looking for a W-9, payment info or something else?CLICK HERE FOR RESOURCES

homepage

Square-D / Schneider - SQD EX500T63HCT Transformer, dry ty

CopyCopy

Login or create an account to check prices & order

Essential specifications

  • 12-Digit UPC - 785901751151

  • Catalog Number - EX500T63HCT

  • Country of Origin - USA

  • Depths - 963 mm

  • ERP_productname - SQD EX500T63HCT TRANSFORMER, DRY TYPE, DOE 2016, 500KVA, 3 PHASE, 480V DELTA PRIMARY, 240V DELTA SECONDARY, 30J, 150C RISE, 120V CTR

Packaging

  • 1 ea

EAN

00785901751151

Part #

405729

Catalog #

EX500T63HCT

Commercial reference

EX500T63HCT

12-Digit UPC:

785901751151

Catalog Number:

EX500T63HCT

Country of Origin:

USA

Depths:

963 mm

ERP_productname:

SQD EX500T63HCT TRANSFORMER, DRY TYPE, DOE 2016, 500KVA, 3 PHASE, 480V DELTA PRIMARY, 240V DELTA SECONDARY, 30J, 150C RISE, 120V CTR

Family Brand Name:

Square D

Heights:

1803 mm

Material:

Aluminum

Number of Phases:

3 Phase

Primary Voltage:

480 V

Secondary Voltage:

120 V

Voltage:

480 Volt

Widths:

1226 mm

SoneparProductId:

SKU_US_126141839

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 500kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer.s DOE 2016 and NRCan efficiency is a minimum of 99.14% at 35% loading and 75.C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of . inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values. Prop 65: WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov