We Rebranded! Looking for a W-9, payment info or something else?CLICK HERE FOR RESOURCES

homepage

Square-D / Schneider - SQD XPSATE5110P SAFETY RELAY WITH TIMING FUNCTION, 24 V

CopyCopy

Login or create an account to check prices & order

Essential specifications

  • 12-Digit UPC - 785901573944

  • Applications - EMERGENCY STOP BUTTON WITH 2 NC CONTACTS,FOR EMERGENCY STOP AND SWITCH MONITORING

  • Catalog Number - XPSATE5110P

  • Country of Origin - Indonesia

  • ERP_productname - SQD XPSATE5110P SAFETY RELAY WITH TIMING FUNCTION, 24 V

Packaging

  • 1 ea

EAN

03389119004046

Part #

152762

Catalog #

XPSATE5110P

Commercial reference

XPSATE5110P

12-Digit UPC:

785901573944

Applications:

EMERGENCY STOP BUTTON WITH 2 NC CONTACTS,FOR EMERGENCY STOP AND SWITCH MONITORING

Catalog Number:

XPSATE5110P

Country of Origin:

Indonesia

ERP_productname:

SQD XPSATE5110P SAFETY RELAY WITH TIMING FUNCTION, 24 V

Family Brand Name:

Schneider Electric

Tc Connection:

CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.2...1 X 2.5 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.2...1 X 2.5 MMA. SOLID WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.25...1 X 2.5 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.2...2 X 1 MMA. SOLID WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.2...2 X 1.5 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.25...2 X 1 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.5...2 X 1.5 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL

Type:

PREVENTA SAFETY MODULE

SoneparProductId:

SKU_US_30886758

This XPSATE safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 (instantaneous safety outputs), PL d/Category 3 (time delayed safety outputs) conforming to EN/ISO 13849-1. It meets also the requirements of SILCL3 (instantaneous safety outputs) and SILCL2 (time delayed safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring Emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards, and electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.