Essential specifications

  • 12-Digit UPC - 785901452430

  • Applications - For emergency stop and switch monitoring

  • Catalog Number - XPSABV1133P

  • ERP_productname - SQD XPSABV1133P SAFETY RELAY FOR E-STOP, GUARDS, 24 VDC

  • Enclosure - IP20 CONFORMING TO EN/IEC 60529, IP40 CONFORMING TO EN/IEC 60529

Packaging

  • 1 ea

EAN

03389118376076

Part #

122450

Catalog #

XPSABV1133P

Commercial reference

XPSABV1133P

12-Digit UPC:

785901452430

Applications:

For emergency stop and switch monitoring

Catalog Number:

XPSABV1133P

ERP_productname:

SQD XPSABV1133P SAFETY RELAY FOR E-STOP, GUARDS, 24 VDC

Enclosure:

IP20 CONFORMING TO EN/IEC 60529, IP40 CONFORMING TO EN/IEC 60529

Family Brand Name:

Telemecanique

Sub Brand:

PREVENTA

Tc Connection:

CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.2...1 X 2.5 MMA. SOLID WITHOUT CABLE END-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.2...1 X 2.5 MMA. FLEXIBLE WITHOUT CABLE END-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.25...1 X 2.5 MMA. FLEXIBLE WITH CABLE END, WITHOUT BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 1 X 0.25...1 X 1.5 MMA. FLEXIBLE WITH CABLE END, WITH BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.2...2 X 1 MMA. SOLID WITHOUT CABLE END-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.2...2 X 1 MMA. FLEXIBLE WITHOUT CABLE END-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.25...2 X 1 MMA. FLEXIBLE WITH CABLE END, WITHOUT BEZEL-CAPTIVE SCREW CLAMP TERMINALS, REMOVABLE TERMINAL BLOCK, 2 X 0.5...2 X 1 MMA. FLEXIBLE WITH CABLE END, WITH DOUBLE BEZEL

Type:

Preventa safety module

SoneparProductId:

SKU_US_315897166

This XPSABV safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 (instantaneous safety outputs), PL d/Category 3 (time delayed safety outputs) conforming to EN/ISO 13849-1. It meets also the requirements of SILCL3 (instantaneous safety outputs) and SILCL2 (time delayed safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring Emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards, and electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.