Combination Fittings
79 products
12-Digit UPC: 781747092854
Applications: Bridgeport now offers a full line of EMT to FMC/Greenfield Transition Couplings. You no longer need to assemble multiple fittings, or mount a box, to transition between raceways. These couplings provide dimensional flexibility for a raceway system when dropping in to switchgear and transitioning into transformers. Patented
Catalog Number: 285-DC
Login or create an account to check prices & order12-Digit UPC: 781747092816
Applications: Used to join EMT to flexible metal conduit. 281-DC is squeeze type for flexible metal conduit. Set screw type for EMT end.
Catalog Number: 281-DC
Login or create an account to check prices & order12-Digit UPC: 781747092823
Applications: Used to join EMT to flexible metal conduit. 282-DC is squeeze type for flexible metal conduit. Set screw type for EMT end.
Catalog Number: 282-DC
Login or create an account to check prices & order12-Digit UPC: 781747092809
Applications: Used to join 1/2" EMT and up to two 14/2 and 12/2 Romex, Non-Metallic Cables. Two screw strap type for cable and a set screw type for EMT.
Catalog Number: 280-DC
Login or create an account to check prices & order12-Digit UPC: 781747292827
Applications: Bridgeport now offers a full line of Mighty-Merge Rigid to FMC/Greenfield Transition Fittings. An easy and Listed way to transition between Threadless Rigid and FMC. These couplings provide dimensional flexibility for a raceway system when dropping in to switchgear and transitioning into transformers.
Catalog Number: 282-DCR
Login or create an account to check prices & order12-Digit UPC: 785991444247
Applications: For use with EMT conduit
Catalog Number: TX 222
Login or create an account to check prices & order12-Digit UPC: 784564106926
Applications: EMT Conduit
Catalog Number: 692
Login or create an account to check prices & order- Copy
- Copy
12-Digit UPC: 781747941565
Applications: The 4156-DC is used to securely join 1/2" EMT to two 14/2 to 10/3 (.43" to .61" Diameter) AC/MC/MCI-A/HCF/HCFMCI-A or 3/8" flexible metal conduit. These fittings provide a huge labor savings, compared to the traditional junction box or fitting assembly installation. When using AC/MC/FMC cable simply remove the armor and expose the conductors to the desired length needed to reach the device box or enclosure. The inspection holes will provide a visual end stop for the cable or flex conduit. The use of anti short bushings is recommended. Tighten the steel screws for the 1/2" EMT conduit. Patented.
Catalog Number: 4156-DC
Login or create an account to check prices & order12-Digit UPC: 018997086006
Catalog Number: 8600
Color: Silver
Login or create an account to check prices & order12-Digit UPC: 781747940582
Applications: Combination Couplings used to join 3/4" EMT conduit via set screw to 10/4 through 6/4 Steel and Aluminum AC/MC/MCIA, and 1/2" Steel and Aluminum FMC. Patented
Catalog Number: 4058-DC
Login or create an account to check prices & order12-Digit UPC: 781747095824
Applications: Used to join EMT to flexible metal conduit. Screw-in type for flex. Compression type for EMT.
Catalog Number: 582-DC
Login or create an account to check prices & order12-Digit UPC: 018997008602
Catalog Number: 860
Color: Silver
Login or create an account to check prices & order12-Digit UPC: 781747092830
Applications: Set screw type couplings used to join EMT to flexible metal conduit.
Catalog Number: 283-DC
Login or create an account to check prices & order12-Digit UPC: 781747092793
Applications: Transition fitting for use between 1/2" EMT to 3/8" Steel and Aluminum FMC, metal clad and armored cable assemblies with O.D. of .43-.61 (14/2 to 10/3 within the specified ranges), as well as 14/2 to 10/3 NM Cables, (2) 14/2 or (2) 12/2 NM Cables stacked, or the following combinations: 14/2 & 12/2, 14/2 & 12/3, 14/3 & 12/2. AC/MC should be prepared to the desired length and fed through the fitting. AC/MC/MCIA and FMC should be inserted until the armor engages with the endstop at the center of the fitting. Use of Antishort bushings is required on AC/MC cables.
Catalog Number: 280-DCX
Login or create an account to check prices & order12-Digit UPC: 662277028172
Applications: Flexible Metal Conduit
Catalog Number: FECS75DC
Login or create an account to check prices & order12-Digit UPC: 781747712806
Applications: For use transitioning between 1/2" EMT and 14/2 to 10/3 AC/MC/MCIA or 3/8" FMC. These zinc die cast couplings are ideal for transitioning fixture whips above a drop ceiling for continuing a run of MC down the wall to emergency lights.
Catalog Number: 280SPMB
Login or create an account to check prices & order- Copy
- Copy
12-Digit UPC: 781747943606
Applications: Used to join either metallic or non-metallic (Type "B") liquid tight conduit to EMT. Raintight. Concrete-Tight.
Catalog Number: 4360-DC
Login or create an account to check prices & order12-Digit UPC: 662277028134
Applications: Flexible Metal Conduit
Catalog Number: FECC75DC
Login or create an account to check prices & order12-Digit UPC: 781747928214
Applications: Set screw type couplings used to join EMT to flexible metal conduit.
Catalog Number: 282-DCX
Login or create an account to check prices & order12-Digit UPC: 781747092847
Applications: Bridgeport now offers a full line of EMT to FMC/Greenfield Transition Couplings. You no longer need to assemble multiple fittings, or mount a box, to transition between raceways. These couplings provide dimensional flexibility for a raceway system when dropping in to switchgear and transitioning into transformers. Patented
Catalog Number: 284-DC
Login or create an account to check prices & order12-Digit UPC: 781747940575
Applications: Combination Couplings used to join 3/4" EMT conduit via set screw to 14/2 through 10/3 Steel and Aluminum AC/MC/MCIA, and 3/8" Steel and Aluminum FMC. Patented
Catalog Number: 4057-DC
Login or create an account to check prices & order12-Digit UPC: 781747702807
Applications: Mighty-Merge® Transition fitting for use between 1/2 inch EMT to 3/8 inch FMC, metal clad and armored cable assemblies with O.D of .43 to .61 (14/2 to 10/3 within the specified ranges). AC/MC should be prepared to the desired length and fed through the fitting. AC/MC/MCIA and FMC should be inserted until the armor is visible in the sight hole at the center of the fitting. Use of Antishort bushings is required on AC/MC cable and recommended with FMC. Fitting unthreads from end of cable assembly and FMC. For dry locations only. Patented
Catalog Number: 280SP
Login or create an account to check prices & order- Copy
- Copy
12-Digit UPC: 785991908626
Applications: For use with EMT conduit
Catalog Number: TX210
Login or create an account to check prices & order12-Digit UPC: 781747942623
Applications: Used to make transition from Rigid Metallic Conduit and IMC to EMT in wet and dry locations.
Catalog Number: 292-RT
Login or create an account to check prices & order