Appleton EYF-75 3/4" Explosion Proof Sealing Unilet

Manufacturer: Appleton Electric | Catalog # EYF75 | Echo Electric Part # 180897

$33.64/ea
ea
Log in or register to view your price, purchase history, and more!
0

Not Available for Pickup at Springfield, IL Opens Monday 7:00am CT
138 available

For Delivery

Not in local stock *
Check another branch
Appleton™ EY 25% fill vertical and horizontal conduit sealing fittings prevent the passage of gases, vapors or flames from one portion of a conduit system to another. They also restrict large amounts of ignitable gases or vapors from accumulating to confine explosive pressure. Appleton sealing fittings are explosionproof, dust-ignitionproof and raintight. They are suitable for use in Class I and II locations.

Technical Information

Applications
For Use With Threaded Rigid Metal Conduit and IMC
Material
Iron
Size
3/4 IN
TC Connection
Female Threaded
Trade Size
3/4 Inch
Type
25% Fill Vertical and Horizontal, Explosionproof, Female

Manufacturer Information

Brand
Appleton
Sub Brand
Unilet

General Product Info

12-Digit UPC
781381135122
Finish
Zinc
GTiN
00781381135122
Product UPC
78138113512
Used With
Threaded Rigid Metal Conduit and IMC
Features
  • Explosionproof, dust-ignitionproof, raintight
  • Prevent passage of gases, vapors or flames from one portion of conduit system to another. Restrict any explosion to the sealed off enclosure. Prevent pressure piling within conduit system
  • Required in Class I, Division 1 and 2 locations within 18\" of enclosures containing apparatus that may cause arcs, sparks or high temperatures
  • Required in Class I, Division 1 and 2 locations where 2\" or larger conduit enters enclosure, fitting housing terminals, splices or taps
  • Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
  • Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36\" or less conduit. Seal must be located within 18\" of either enclosure
  • Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations
  • Smooth, rounded integral bushing in each hub protects conductor insulation
  • Accurately tapped, tapered threads for tight, rigid joints and ground continuity
  • Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
  • UL Listed for use with Kwiko™ A Sealing Compound. Also listed with certain competitors sealing cement, contact factory for details
  • Close radius type for sealing vertical or horizontal conduit runs